Electric Guardlamps Switches
- IL201-U
- IL201E-N
- Overview
- Compatible between electronic type and GPS type units
- Functions
- • Time for power failure compensation is unnecessary
- • Able to check power, output display lamp and lighting
- • Attachment/detachment is easy and convenient at the time of A/S
- • Design with the minimized influence from the external light
- • Function to select lighting type according to the installed
environment (Electric pole, Surface of the wall) - • Electronic · GPS unit compatible

Electronic Switches for Guardlamps
- ILDR-U
- ILDR503E-B
- Overview
- A product for subdivided control by sunrise/ sunset and twilight time by the time IC embedded programmed CPU.
- Functions
- • All functions are displayed in LCD Screen
- • Data check and setup by simple control
- • Light On/Off compensation function (±180 minutes applied)
- • Able to check power, output display lamp and lighting
- • Power failure compensation function
- • Automatic leap year compensation function
- • Light Off at midnight (Alternate lighting 1),
Lighting again at midnight(Alternate lighting 2)
- Electric features
- • Voltage:AC 220 V ±10%
- • Frequency : 60 Hz
- • Maximum load : AC 220 V 5 A
- • Maximum output load : AC 220 V 5 A, Less
Than 400w - • Controller current : 20 mA
- • Temperature : -30°C ~ 80°C
- • Humidity : 5 - 95%

GPS Switches for Guardlamps
- ILG505-U
- ILG505E-B
- Overview
- Consistent control is available by always maintaining the standard time in application of GPS receipt
for compensating the present time to the electronic Guard Lamp switch, and this product does not require
a separate compensation because the light On/Off time according to the region is compensated automatically.
- Functions
- • Automatic compensation function of the standard time
- • Automatic compensation for Light On/Off time
according to the installed area - • All functions are displayed in LCD Screen
- • Data check and setup by simple control
- • Light On/Off compensation function (±180 minutes applied)
- • Able to check power, output display lamp and lighting
- • Power failure compensation function (8,000h)
- • Function to select lighting type according to the installed
environment - • Automatic leap year compensation function
- • Light Off at midnight (Alternate lighting 1),
Lighting again at midnight(Alternate lighting 2)
- Electric features
- • Voltage:AC 220 V ±10%
- • Frequency : 60 Hz
- • Maximum load : AC 220 V 5 A
- • Maximum output load : AC 220 V 5 A, Less
than 400w - • Controller current : 20 mA
- • Temperature : -30°C ~ 80°C
- • Humidity : 5 - 95%